Structural calculations for a multi-storey steel frame
We produced the structural calculations for a multi-storey steel frame with horizontal T-connections for the owners’ association on the Wattlaan.
For the owners’ association on the Wattlaan we took care of the structural calculations for an extensive steel frame spread over several storeys. A precise structural analysis was central to this project, with particular attention to the stability of the steel structure and the correct transfer of loads to the foundations.
The steel frame consists of several storeys that are structurally connected both vertically and horizontally. T-connections were used in the horizontal plane, giving an efficient distribution of forces and extra stability within the main load-bearing structure.
The calculations took into account various load combinations, including permanent loads, variable loads and the related safety factors under the applicable Eurocodes. Using RFEM and IDEA StatiCa, the steel structure, connections and joints were analysed and checked for strength, stiffness and stability.
Throughout the engineering process we worked closely with the parties involved to match the structural solutions to the existing situation and the wishes of the owners’ association. The result is a reliable, future-proof steel structure with a solid structural basis for long-term use.